Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of the Korean Ophthalmological Society ; : 362-368, 1998.
Article in Korean | WPRIM | ID: wpr-149044

ABSTRACT

There have been limited reports about the prevalence and its characteristics of glaucoma in Korea. To clarify further, we retrospectively analyzed the data of 1482 patients with glaucoma from January 1993 to December 1994. The prevalence of glaucoma was 0.58%. The type of glaucoma consisted of secondary glaucoma 33.9%, primary open angle glaucoma(POAG) in 33.2%, angle closure glaucoma(ACG) 28.0%, normal tension glaucoma 4.0% and congenital glaucoma 0.9%. The mean age of the patients with POAG was 55.2+/-16.5 and that of ACG was 64.7+/-9.2. In POAG, the age group over 40 years old occupied 79.7% while 99.3% was the age group over 40 years in ACG. The incidence rate of men was higher than women in POAG but in women it was 3.6 times higher than men in ACG. Secondary glaucomas due to diseases of uveal tract, neovascular glaucoma, steroid induced glaucoma, and aphakic (or pseudophakic) glaucoma were 37.0%, 18.9%, 16.5%, and 15.7% respectively.


Subject(s)
Adult , Female , Humans , Male , Glaucoma , Glaucoma, Angle-Closure , Glaucoma, Neovascular , Incidence , Korea , Low Tension Glaucoma , Prevalence , Retrospective Studies
2.
Journal of the Korean Ophthalmological Society ; : 1622-1627, 1997.
Article in Korean | WPRIM | ID: wpr-30577

ABSTRACT

Moderate to severe unilateral ptosis has previously been treated with levator resection or frontalis sling and cosmetic double fold in the opposite eyelid. This method often resulted in undesirable asymmetrical lid lag phenomenon in down gaze. From December 1991 to December 1994, we treated 65 cases of unilateral ptosis with frontalis sling or levator resection, and simultaneously cosmetic frontalis sling have been performed in the unaffected normal eyes of 41 patients and cosmetic double fold have been performed in the unaffected normal eyes of 11 patients. After 6 months of operation, authors survey the patients content. The number of cases of content were 4(36.36%) in 11 cosmetic double fold group and 31(75.6%) in 41 cosmetic frontalis sling group. The content after cosmetic frontalis sling was higher than cosmetic double fold. Asymmetrical lid lag phenomenon on downward gaze which is inevitable complication postoperatively was reduced by means of cosmetic frontalis sling of unafeected normal eye in unilatral ptosis. The authors expect that the patient will be more satisfied with the result of symmetrical lid lag in down gaze after cosmetic frontalis sling of unaffected normal eye in aesthetic aspect.


Subject(s)
Humans , Eyelids
SELECTION OF CITATIONS
SEARCH DETAIL